PCS - EQ-DA Controller (web)
CUSTOMER SPECIFIED SETTINGS:
Pcalibrated: XX barg
Inlet pressure, fill: 10% above maximum pressure range
Outlet pressure, relief: 0 barg
Internal sensor configuration: XX barg
DEVICE HARDWARE SPECIFICATIONS:
Fluid: N2/Air
Pressure controlled volume: 5 cc
Valve seals: FKM
Plunger: FKM
Valve function: Normally closed
Classification: IP-65
Temperature rating: -10 to 50 °C
Accuracy internal sensor: ± 0.25% FS at calibration conditions
Repeatability: ≤ 0.01% RD
ELECTRICAL INFORMATION:
Supply voltage: +24 Vdc
Analog I/O: 4…20mA | 0…5Vdc | 0…10Vdc | 0...20mA
Digital I/O: RS485 MODBUS RTU and USB-C virtual COM port MODBUS RTU
By default, setpoint via analog input C + measured value via analog output C